Skip to main navigation Skip to search Skip to main content

The safety and effectiveness of the woven endobridge (web) system for the treatment of wide-necked bifurcation aneurysms: Final 12-month results of the pivotal web intrasaccular therapy (web-it) study

  • Adam S. Arthur
  • , Andy Molyneux
  • , Alexander L. Coon
  • , Isil Saatci
  • , Istvan Szikora
  • , Feyyaz Baltacioglu
  • , Ali Sultan
  • , Daniel Hoit
  • , Josser E. Delgado Almandoz
  • , Lucas Elijovich
  • , Saru Cekirge
  • , James V. Byrne
  • , David Fiorella
  • Semmes Murphey Neurologic & Spine Institute
  • University of Tennessee Health Science Center
  • University of Oxford
  • Johns Hopkins University
  • Private Koru Hospital
  • National Institute of Clinical Neurosciences
  • Marmara University
  • Brigham and Women’s Hospital
  • Allina Health
  • Koru Hospital
  • Private Office
  • John Radcliffe Hospital

Research output: Contribution to journalArticlepeer-review

321 Scopus citations

Abstract

Introduction The Woven EndoBridge Intrasaccular Therapy (WEB-IT) Study is a pivotal, prospective, single-arm, investigational device exemption study designed to evaluate the safety and effectiveness of the WEB device for the treatment of wide-neck bifurcation aneurysms. Methods One-hundred and fifty patients with wide-neck bifurcation aneurysms were enrolled at 21 US and six international centers. Angiograms from the index procedure, and 6-month and 1-year follow-up visits were all reviewed by a core laboratory. All adverse events were reviewed and adjudicated by a clinical events adjudicator. A data monitoring committee provided oversight during the trial to ensure subject safety. Results One-hundred and forty-eight patients received the WEB implant. One (0.7%) primary safety event occurred during the study - a delayed ipsilateral parenchymal hemorrhage - on postoperative day 22. No primary safety events occurred after 30 days through 1 year. At the 12-month angiographic follow-up, 77/143 patients (53.8%) had complete aneurysm occlusion. Adequate occlusion was achieved in 121/143 (84.6%) subjects. Conclusions The prespecified safety and effectiveness endpoints for the aneurysms studied in the WEB-IT trial were met. The results of this trial suggest that the WEB device provides an option for patients with wide-neck bifurcation aneurysms that is as effective as currently available therapies and markedly safer.

Original languageEnglish
Pages (from-to)924-930
Number of pages7
JournalJournal of NeuroInterventional Surgery
Volume11
Issue number9
DOIs
StatePublished - Sep 1 2019