TY - GEN
T1 - Thermal zones for more efficient data center energy management
AU - Hamann, Hendrik F.
AU - López, Vanessa
AU - Stepanchuk, Andrew
PY - 2010
Y1 - 2010
N2 - The optimization of cooling resources within data centers (DCs), which includes the localized provisioning of cooling power with respect to the heat dissipation, can lead to significant reduction of energy consumption [1]. While such matching is rather straightforward for the entire DC, on a more granular level however, the large range of heat densities of today's IT equipment has made this task much more challenging. One complication comes from the fact there is little operational information, for example, which physical areas (or zones) are supplied by the different air conditioning units (ACUs) so that local cooling demands can be met [2]. Evidently, such zones are not only determined by the placement and air flow produced by each ACU but also by the locations of perforated tiles throughout the DC and many other parameters. Here we present a general methodology for determining such zones. Specifically, we use a simplified physics model to calculate the air flow velocity field within the DC [3,4,5]. The novelty of the approach is that the boundary conditions are obtained from real-time measurements. Once the air flow pattern is calculated, we deploy an efficient tracing algorithm, which follows the air from/to each area of the DC back to the originating/returning ACU. The trace connects a specific ACU with its related zone. Each zone can be associated with the actual efficiency of the corresponding ACU by considering the respective utilization of the units (heat removed / nominal heat load removal capacity) or coefficient of performance (COP=heat removed / power consumption for ACU fans). Both COP and ACU utilization can be obtained from real-time temperature and air flow measurements. The paper will also discuss a software tool, which helps operators to use this information for improving DC energy efficiency.
AB - The optimization of cooling resources within data centers (DCs), which includes the localized provisioning of cooling power with respect to the heat dissipation, can lead to significant reduction of energy consumption [1]. While such matching is rather straightforward for the entire DC, on a more granular level however, the large range of heat densities of today's IT equipment has made this task much more challenging. One complication comes from the fact there is little operational information, for example, which physical areas (or zones) are supplied by the different air conditioning units (ACUs) so that local cooling demands can be met [2]. Evidently, such zones are not only determined by the placement and air flow produced by each ACU but also by the locations of perforated tiles throughout the DC and many other parameters. Here we present a general methodology for determining such zones. Specifically, we use a simplified physics model to calculate the air flow velocity field within the DC [3,4,5]. The novelty of the approach is that the boundary conditions are obtained from real-time measurements. Once the air flow pattern is calculated, we deploy an efficient tracing algorithm, which follows the air from/to each area of the DC back to the originating/returning ACU. The trace connects a specific ACU with its related zone. Each zone can be associated with the actual efficiency of the corresponding ACU by considering the respective utilization of the units (heat removed / nominal heat load removal capacity) or coefficient of performance (COP=heat removed / power consumption for ACU fans). Both COP and ACU utilization can be obtained from real-time temperature and air flow measurements. The paper will also discuss a software tool, which helps operators to use this information for improving DC energy efficiency.
KW - CFD modeling
KW - Data center
KW - Energy efficiency
KW - Energy management
KW - Potential flow
KW - Thermal management
UR - https://www.scopus.com/pages/publications/77955184386
U2 - 10.1109/ITHERM.2010.5501332
DO - 10.1109/ITHERM.2010.5501332
M3 - Conference contribution
AN - SCOPUS:77955184386
SN - 9781424453429
T3 - 2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010
BT - 2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010
T2 - 2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010
Y2 - 2 June 2010 through 5 June 2010
ER -