Skip to main navigation Skip to search Skip to main content

Validity and reliability of a new food frequency questionnaire compared to 24h recalls and biochemical measurements: Pilot phase of Golestan cohort study of esophageal cancer

  • A. F. Malekshah
  • , M. Kimiagar
  • , M. Saadatian-Elahi
  • , A. Pourshams
  • , M. Nouraie
  • , G. Goglani
  • , A. Hoshiarrad
  • , M. Sadatsafavi
  • , B. Golestan
  • , A. Yoonesi
  • , N. Rakhshani
  • , S. Fahimi
  • , D. Nasrollahzadeh
  • , R. Salahi
  • , A. Ghafarpour
  • , S. Semnani
  • , J. P. Steghens
  • , C. C. Abnet
  • , F. Kamangar
  • , S. M. Dawsey
  • P. Brennan, P. Boffetta, R. Malekzadeh
  • Tehran University of Medical Sciences
  • Shahid Beheshti University of Medical Sciences
  • International Agency for Research on Cancer
  • Hôpital Édouard Herriot
  • Golestan University of Medical Sciences
  • National Institutes of Health

Research output: Contribution to journalArticlepeer-review

211 Scopus citations

Abstract

Background: A pilot study was carried out to evaluate validity and reproducibility of a food frequency questionnaire (FFQ), which was designed to be used in a prospective cohort study in a population at high risk for esophageal cancer in northern Iran. Methods: The FFQ was administered four times to 131 subjects, aged 35-65 years, of both sexes. Twelve 24-h dietary recalls for two consecutive days were administered monthly during 1 year and used as a reference method. The excretion of nitrogen was measured on four 24-h urine samples, and plasma levels of β-carotene, retinol, vitamin C and α-tocopherol was measured from two time points. Relative validity of FFQ and 24-h diet recall was assessed by comparing nutrient intake derived from both methods with the urinary nitrogen and plasma levels of β-carotene, retinol, vitamin C and α-tocopherol. Results: Correlation coefficients comparing energy and nutrients intake based on the mean of the four FFQ and the mean of twelve 24-h diet recalls were 0.75 for total energy, 0.75 for carbohydrates, 0.76 for proteins and 0.65 for fat. Correlation coefficients between the FFQ-based intake and serum levels of β-carotene, retinol, vitamin C and vitamin E/α-tocopherol were 0.37, 0.32, 0.35 and 0.06, respectively. Correlation coefficients between urinary nitrogen and FFQ-based protein intake ranged from 0.23 to 0.35. Intraclass correlation coefficients used to measure reproducibility of FFQ ranged from 0.66 to 0.89. Conclusion: We found that the FFQ provides valid and reliable measurements of habitual intake for energy and most of the nutrients studied.

Original languageEnglish
Pages (from-to)971-977
Number of pages7
JournalEuropean Journal of Clinical Nutrition
Volume60
Issue number8
DOIs
StatePublished - Aug 2006

Fingerprint

Dive into the research topics of 'Validity and reliability of a new food frequency questionnaire compared to 24h recalls and biochemical measurements: Pilot phase of Golestan cohort study of esophageal cancer'. Together they form a unique fingerprint.

Cite this